Plastic scintillators are used for Gamma-ray detection. They are widely used in various applications, such as isotope gauge, vehicle radiation detection and environmental radiation monitoring systems. Plastic Scintillators offer high performance, ease of handling, and mechanical stability at a relatively low cost. The versatility of plastic Scintillators makes them the ideal choice for large area and specially shaped detectors.

Autumn

1. Form of product:

  • - Sheet sizes range up to 120" (3m) long by 36" (914mm) wide.
  • - Blocks up to 96" (2.5m) long
  • - Rods up to 48" (1220mm) diameter
  • - Customized sizes and shapes are available

General properties

Polymer Base Polyvinyl toluene
Density , g/cc 1.032
Refractive Index (ND): 1.58
Softening Point 70C
Coeff. of Linear Expansion (<67C): 7.8x10-5 / C
Vapour Pressure Negligible. May be used in high vacuum.
Light Output vs. Temperature Independent of temperature@ -60C to 20C At +60C is 95% of that at +20C
Radiation Length: 43cm

Scintillation properties

Light Output % Anthracene 64
Scintillation Efficiency Photons/ MeV 10,000
Wavelength of Max. Emission, nm 425
Rise Time, ns 0.9
Decay Time, ns 2.1
PulseWidth, FWHM, ns 2.5
Atomic Ratio, H/C 1.10
No. of H Atoms per cm3, x 1022 5.23
No. of C Atoms per cm3, x 1022 4.74

Contact us for standard sizes of annuli, well counters, thin films and spheres.